LK Automation Limited
Home >> Products >> MITSUBISHI >> R series PLC >> CPU module >> R64MTCPU MITSUBISHI R64MTCPU 

R64MTCPU MITSUBISHI R64MTCPU 

Brand: MITSUBISHI
Name: Movement CPU
Model: R64MTCPU

Capacity: 2MB.Input supply voltage: DC24V.
Input frequency: -.
Input maximum apparent power: -.
Maximum input power: 50.
Rated output current (DC5V): 6.5A.
Rated output current (DC24V): -.
IQ-R MELSEC series consists of CPU module, power module, substrate module, input and output module, intelligent function module and so on MITSUBISHI R64MTCPU.
For the entire system, the substrate module can be expanded to 7 levels, up to 64 modules can be installed,
Therefore, large scale system can be constructed R64MTCPU In addition, by using the RQ extended substrate module,
The sea can also effectively use the MELSEC-Q series of modules of the asset. Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0 MITSUBISHI R64MTCPU. 1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: plus or minus 15V.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: - MITSUBISHI R64MTCPU.
Digital output value: -.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference MITSUBISHI Terminal module.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data MITSUBISHI Terminal module.
Reduce downtime and reduce maintenance costs through anomaly detection
Works3 GX can be used to easily set the critical value of the input and output signals.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs.
Channel insulation can ensure the accurate signal transceiver MITSUBISHI Terminal module.
Model with " -G " module in the channel between the insulation,
Isolation amplifiers are not required to prevent inter channel current and interference current. Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 1200K.
Increase the speed of a constant cycle interrupt program.
Perform a minimum interval constant period interrupt program can be shortened to 50 s,
Programmable logic controller can read more high-speed signals.
In addition, it can also be a priority for the interrupt program,
Interrupt routine with high priority when interrupt processing.
Therefore, when the signal is read at a high speed, the program can read the signal from the constant cycle of the conventional input module +CPU module.
Program capacity: 1200K.
Program capacity of up to 1200K.
Multi CPU system for high precision motion control.
The built-in CPU module support 2 Gigabit Network port.
Database functions to facilitate data manaagement R64MTCPU.
Extended SRAM card with built-in security function.
Can be carried out a variety of motion control (position, speed, torque, advanced synchronous control, etc.).
In line with the international safety standards (13849-1 PPL e ISO, IEC 61508 SIL 3) security CPU MITSUBISHI R64MTCPU.
The most suitable for C/C++ language programming from the computer / computer environment for transplantation.


...More relevant models >>>>